ST 310 Drinking Water Installation Demonstrator Didactic Equipment Vocational Education Equipment Water Treatment Trainer
Drinking water installation in domestic setting with all common components Features - trainer with all components common in a drinking water installation - designed for training in the plumbing sector Learning objectives/experiments - function and operation of components -- water meter -- pressure reducing valve with and without reversible flow filter -- backflow preventer / system separator -- system of safety devices -- pressure vessel with heater -- circulating pump -- thermal discharge safety device Specification [1] familiarisation with the most important components in a drinking water installation [2] system divided into cold water side, hot water side, drain system [3] cold water circuit with water meter, pressure reducing valve, angle-seat valve, system separator, outlets [4] hot water circuit with system of safety devices, pressure vessel with heater, pressure reducing valve, non-return valve, circulating pump with timer, outlets [5] drain system on rear of panel, drain pipe DN 40 with high temperature stability [6] single handle mixer, two handle mixer, shower sprinkler, pipe vents Technical data Vane impeller water meter DN20: 2.5m3/h Euro system separator BA, hazard class 4 System of safety devices, 6bar - backflow preventer - pressure reducing valve - shut-off valve Thermal discharge safety device: 95°C Threaded heater element 3kW (in pressure vessel) Pump - power consumption: 20W - max. flow rate: 640L/h - max. head: 1,4m - max. operating temperature: 110°C Measuring ranges pressure: 3x 0...10bar 230V, 50Hz, 1 phase 230V, 60Hz, 1 phase 230V, 60Hz, 3 phases LxWxH: 2000x700x1900mm Weight: approx. 163kg